These models require 94% to 95% oxygen input @ 60 psig to deliver oxygen at 99.5%. Rated flow is 65% to 75% of input flow. Output ranges are 1 Nm3/Hr to 50 Nm3/Hr. Product oxygen at 99.5% is available up to 100 psig storage pressure.

They are offered as retrofit only when primary oxygen supply meets OXAIR’s OX-HP Series criteria of 95% purity.

Features:

Download

Download brochure

  • These models consist of 99.5% purifier module and recompression system.
  • Feed oxygen supply should be a minimun of 60 psig.
  • Touch screen control.

Specifications:

MODELPSA O2
Input @ 95%
O2 output
@ 99%
O2 Booster (1)O2 Booster (2)Specific Power (3)PSA Power
(compressor + dryer) (4)
Total Oxygen Generation Power (5)Specific Power (6)
ScfhNm3/hrScfhNm3/hrInstalled HpAbsorbed power KwKw/Nm3HPKwHPKw
OP-21604.2962.51.50.700.28118.2123.5
OP-32245.91343.52.00.880.251511.2163.4
OP-43007.91804.72.01.090.232115.6223.5
OP-640010.52406.33.01.360.222720.1293.4
OP-1060015.83308.73.01.710.203727.6393.3
OP-1275019.745011.83.02.200.195339.5563.5
OP-16100026.359915.85.02.780.186548.4683.2
OP-20127533.576420.15.03.540.187656.6803.0
OP-26170044.7101926.87.54.720.1810477.51093.0
OP-40255067.0152840.210.07.080.18155115.51623.0
OP-50300078.9185848.910.08.610.18185137.81932.9

Given specifications are for the generation of high purity oxygen in the range of 99% to 99.5% purity.
Specifications are to be taken with a margin of +/- 5%
(1) Actual motor sizing of the booster/recycler for delivering the high purity oxygen at 99%
(2) Actual power consumed by the booster.
(3) Actual power required to compress one cubic meter of oxygen at 99%.
(4) Typical pwer required in the first stage air separation proces.
(5) Actual power required for the complete high purity installation for first stage air separation and second stage purification.
(6) Actual energy costs to produce 1 cubic meter of oxygen at 99% and 6 bar.